Rated Input Power: 1012W 2500W Outdoor Cabinet Air Conditioner Rated Input Current: 4.6A
Quick Details:
Place of Origin: Shenzhen, China (Mainland)m, | Rated Cooling Capacity : 2600W |
Brand Name: ESTEL | Rated Heating Capacity:300/500W (optional) |
Model: TC06-250JFH/01(KT044 AC220V 60Hz) | Dimension: H×W×D 850×500×271mm |
Product Name: Outdoor Cabinet Air Conditioner | Input Voltage: AC220V/60Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Rated Input Current: 4.6A |
Cover: including outer cover (galvanized steel) | Rated Input Power: 1012W |
Color: grey | Working Temperature: -20°C ~ +55°C |
Protection Level: IP55 | Noise: ≤65dB |
Installation Mode: door mounted | Refrigerant: R410A |
Support OEM | Cooling Method: compressor, active cooling |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | T/T, L/C,DA,DP etc |
Supply Ability: | 16,000 sets per month |
Delivery Time: | 7-15 working days |
Packaging Details: | carton + wooden case + pallet |
1. Specifications
(1) Technical Parameters
Environmental Performance | working environmental temperature | -20°C ~ 55°C |
storage temperature | -40°C ~ 70°C | |
working humidity | ≤95% | |
Thermal Performance | rated cooling capacity | 2800W(L35 L35) 2600W(L25 L35) |
rated heating capacity | 300W/500W (optional) | |
Electrical Performance | rated input current | 4.8A(L35 L35) 4.6A(L25 L35) |
rated input power | 1056W(L35 L35) 1012W(L25 L35) | |
input voltage | AC220V/60Hz (185V~264V) | |
Noise | ≤65dB | |
Reliability | MTBF | 70000h |
Refrigerant | R410A |
Dimension Diagram: H×W×D: 850×500×271mm
2. Description
TC06-250JFH/01(KT044) Air Conditioner is a kind of cooling product developed for outdoor cabinets. It is applicable for the scenarios where internal equipment of the cabinet emits a large quantity of heat and is sensitive to the environment temperature and where the indoor environment needs to be isolated from the outdoor environment completely. This product has full functions, integrating external fan control function. It features high reliability and easy installation and can work immediately upon power on, avoiding complex adjustment.
The internal cycle air path absorbs hot air from the upside, and discharges cold air from the downside of the air conditioner. The external cycle air path absorbs external cold air from the downside, and discharges hot air from the upside after heat exchange.
3. Application
The cabinet air conditioner is widely applied in outdoor telecom cabinet, outdoor battery cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
Wiring Ports:
L N PE : power supply port (voltage input: 220VAC±15% 60Hz)
F+ F- : direct ventilation output port
AL1 AL2: general alarm output port
A+ B- SGND: RS485 communication port
N: not connected pin
The controller includes four types of working modes: operating mode, parameter mode, manual operating mode, and query mode.
(1) Operating Mode:
The mode is normal working mode. There are three operating interfaces which can be selected. The three interfaces display different content. When they are not selected, the interfaces will automatically shift. Press the button “PgDn” to select next display interface; press the button “PgUp” to select the previous display interface.
Interface 1:
Line 1: temperature and humidity inside the thermostatic box (or area I);
Line 2: box air conditioner status, real time clock;
------- cooling start sign;
------- heating start sign;
------- hydrogen exhaust /direct ventilation sign;
-- ------- compressor/ heater stop working.
Interface 2:
Line 1: environment (or area II) temperature and humidity;
Line 2: inside and outside coil temperature display (T3, T4);
Interface 3:
Circularly display current alarms;
When multiple alarms occur, it will display each alarm information circularly.
(2) Parameter Mode:
Function Menu:
(a) Observation Parameter
(b) Control Parameter Revision
(c) Basic Parameter Revision
(d) Manual Operation
(e) Event Query
(f) Return To Operating Mode
a. Check operating parameters of key parts inside air conditioner, namely observation parameter. Operation steps:
Observation Parameter: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
b. Revise operating parameters of air conditioner, namely control parameters. Operation steps:
Control Parameter: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
c. Revise basic parameters of air conditioner. Operation steps:
Basic Parameter: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
(3) Manual Operation Mode:
Operation steps:
Enter the interface to select “Cool” (cooing), “Heater” (heating), “Air” (direct ventilation) to conduct manual start (ON) and stop (OFF) operation.
(4) Event Query Mode:
Operation steps:
9. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
10. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Website: www.estelecomcabinet.com
Tianjin Estel Electronic Science and Technology Co.,Ltd
Introduction
Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and technology innovative company, we engage in the R&D, manufacture, and sales of telecommunication equipment. Estel has a well-established team of technical and management experts who can meet customers’ specific needs accurately.
The base station integrated solutions and products include outdoor integrated telecom equipment cabinet, battery cabinet, RRU cabinet, power supply cabinet, environment monitoring system, TEC peltier air conditioner, AC220V compressor air conditioner, DC48V variable frequency air conditioner, heat exchanger, rectifier, UPS, embedded telecom power system etc. All the above solutions and products can be custom made.
Our products and solutions have been deployed all over China. Our main domestic customers are China Telecom, China Mobile, China Unicom, State Grid, Shenzhen / Beijing Metro and Huawei / ZTE etc. In addition, our products have been exported to Europe, North America, South America, Central America, Southeast Asia, Africa, Australia, Mid East countries, etc.
“ Customers First, Quality First ” is always our principle. We have attained many certifications, such as ISO9001, ISO14001, OHSAS18001, CE, UL, FCC etc. AS a telecom integrated solutions / energy saving system integrator in China, We have strong advantages in technology competitiveness, management competitiveness ,service competitiveness and price competitiveness. Through many years of experiences in design, production and implementation of different projects around the world, we have gained great reputation. Relying on professional technique and strict quality control, we will continuously offer high cost-effective products and solutions to our respectable customers globally. We will always try our best to meet customers’ need and requirement.
Company Capability
Trade & Market
Main Markets | Total Revenue (%) |
Domestic Market | 50.00% |
Africa | 15.00% |
Southeast Asia | 10.00% |
South America | 5.00% |
Central America | 5.00% |
Australia | 3.00% |
Mid East | 3.00% |
North America | 2.00% |
Southern Europe | 2.00% |
Eastern Europe | 1.50% |
Northern Europe | 1.00% |
Western Europe | 1.00% |
South Asia | 1.00% |
Eastern Asia | 0.50% |