Brand Name:ESTEL
Model Number:S02 -A1
Certification:ISO9001, CE, 3C, FCC, TLC,
Price:Negotiation
Payment Terms:T/T, L/C,D/A, Western Union, Paypal, etc
Supply Ability:8,000 sets per month
Delivery Time:10 working days
Company Data
Verified Supplier
Contact Person Fiona Liang
Business Type: Manufacturer Distributor/Wholesaler Exporter
Officials: 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

Non Coding Photoeleciric Smoke Detector AC9V - 35V Working Voltage


1. Prodcut Instruction


The product is a non coding smoke detector, with a pair of switch output contacts, which can choose the normally open and normally closed output according to the actual needs. In normal operation, the indicator light flashes every 8 seconds; in alarm, the indicator light is always on, and the alarm output contact acts at the same time.


2. Product Features


  • Power off reset / automatic reset optional.
  • Alarm output NC / NO optional.
  • 9~35V Wide voltage input without polarity(AC,DC).
  • Network output / LED indicator light alarm / buzzer sound alarm standby.
  • SMT manufacturing process, strong stability.
  • Low static current and power saving.
  • Dust proof, insect proof and white light interference resistant design.
  • Metal shielding, anti RF interference(20V/m—1GHz).

3. Technical Parameters


Working voltageAC9V~35V
Standby current16mA(Relay normally closed) 3mA(Relay normally open)
Alarm current8mA(Relay normally closed) 19mA(Relay normally open)
Alarm indicationRed LED always on
SensorInfrared photoelectric sensor
Working temperature-10℃~+50℃
Environment temperatureMax.95﹪RH(no condensation)
Anti RF interference10MHz—1GHz 20V/m
Alarm output

Normally open/normally closed optional, contact capacity DC28V 100mA

Reset modeAutomatic reset / power off reset optional
Coverage areaWhen the space height is 6m-12m, the protection area of a detector is 80 square meter for general protection site; when the space height is below 6m, the protection area is 60 square meter. The specific parameters shall be subject to the code for design of automatic fire alarm system GB50116-98.
Executive standardGB4716—2005,EN54—7
Sensitivity0.5db/m (±0.1db/m)
External dimension104mm(Diameter)﹡51mm(Height)

4. Product installation


4.1 Select the appropriate installation location, generally installed on the ceiling in the center of the detector coverage area.


4.2 Connect the power line and signal line to the mounting base(mounting base〝1〞and〝2〞are no polarity input for power supply;〝3〞and〝4〞are alarm output contact)


4.3 Description of blue two digit dip switch

"2" corresponds to KT control switch

"1" corresponds to RST control switch


4.3.1 KT alarm output setting

When the KT switch "2" is pulled to the letter "on", the relay is normally closed

When the KT switch "2" is pulled to the letter "off", the relay is normally open


4.3.2 RST alarm mode

When RST switch "1" is pulled to the letter "on", it will reset automatically.

When RST switch "1" is pulled to the letter "off", the power is cut off and reset


4.4 Screw the mounting base to the ceiling


4.5 Align the locating convex point at the base end of the detector with the locating groove of the mounting base, and rotate clockwise to install the detector.


5. Notes


5.1 Pay attention to dust prevention. The dust cover must be removed after the project is officially put into use.


5.2 There shall be no shelter within 0.5m around the detector.


5.3 The horizontal distance between the detector and the air supply hole of the air conditioner shall not be less than 1.5m.


5.4 The horizontal distance between detector and wall, beam edge shall not be less than 0.5m.


5.5 The detector shall be installed in the middle of the inner walkway ceiling with a width of less than 3m. The installation spacing of the detector shall not exceed 15m, and the distance between the detector and the end wall shall not be greater than half of the installation spacing of the control detector.


5.6 The detector should be installed horizontally. For example, the inclination angle of inclined installation should not be greater than 45 degree.


5.7 The detector base shall be installed firmly and its wire connection must be reliable.


5.8 It is recommended to conduct a simulated fire test once half a year to test whether the detector works normally.


6. Package Pictures


AC 9V-35V Security Monitoring System Non Coding Photoeleciric Smoke Detector

Company Profile

Tianjin Estel Electronic Science and Technology Co.,Ltd

Introduction 

 

Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and technology innovative company, we engage in the R&D, manufacture, and sales of telecommunication equipment. Estel has a well-established team of technical and management experts who can meet customers’ specific needs accurately.

 

The base station integrated solutions and products include outdoor integrated telecom equipment cabinet, battery cabinet, RRU cabinet, power supply cabinet, environment monitoring system, TEC peltier air conditioner, AC220V compressor air conditioner, DC48V variable frequency air conditioner, heat exchanger, rectifier, UPS, embedded telecom power system etc. All the above solutions and products can be custom made.

 

Our products and solutions have been deployed all over China. Our main domestic customers are China Telecom, China Mobile, China Unicom, State Grid, Shenzhen / Beijing Metro and Huawei / ZTE etc. In addition, our products have been exported to Europe, North America, South America, Central America, Southeast Asia, Africa, Australia, Mid East countries, etc.

 

“ Customers First, Quality First ” is always our principle. We have attained many certifications, such as ISO9001, ISO14001, OHSAS18001, CE, UL, FCC etc. AS a telecom integrated solutions / energy saving system integrator in China, We have strong advantages in technology competitiveness, management competitiveness ,service competitiveness and price competitiveness. Through many years of experiences in design, production and implementation of different projects around the world, we have gained great reputation. Relying on professional technique and strict quality control, we will continuously offer high cost-effective products and solutions to our respectable customers globally. We will always try our best to meet customers’ need and requirement.

 

Company Capability

Trade & Market

 

Main MarketsTotal Revenue (%)
Domestic Market50.00%
Africa15.00%
Southeast Asia10.00%
South America5.00%
Central America5.00%
Australia3.00%
Mid East3.00%
North America2.00%
Southern Europe2.00%
Eastern Europe1.50%
Northern Europe1.00%
Western Europe1.00%
South Asia1.00%
Eastern Asia0.50%

 

 

 

 

 

 

 

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Tianjin Estel Electronic Science and Technology Co.,Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Environment Monitoring System Integrated Tilt And Shock Combination Sensor wholesale

Environment Monitoring System Integrated Tilt And Shock Combination Sensor

China 4 Terminals Wiring Temperature & Humidity Transmitter -20°C - 80°C Operating Temperature wholesale

4 Terminals Wiring Temperature & Humidity Transmitter -20°C - 80°C Operating Temperature

China High Precision Water Detection Sensor Cutomized ISO9001 CE Certification wholesale

High Precision Water Detection Sensor Cutomized ISO9001 CE Certification

China Custom Environment Monitoring System Spot-Type Photoelectric Smoke Sensor Detector wholesale

Custom Environment Monitoring System Spot-Type Photoelectric Smoke Sensor Detector

China ABS Housing Environment Monitoring System Door Sensor  / Alarm Reed Switch wholesale

ABS Housing Environment Monitoring System Door Sensor / Alarm Reed Switch

China Remote Monitoring Environment / Security Monitoring System Support RS485 RS232 wholesale

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

China Environment Monitoring System Intelligently Turn On / Turn Off LED Lamp wholesale

Environment Monitoring System Intelligently Turn On / Turn Off LED Lamp

China Environmental Monitoring Sensors , Water Sensor Switch For Alarming Water Level Inside Cabinet wholesale

Environmental Monitoring Sensors , Water Sensor Switch For Alarming Water Level Inside Cabinet

China Professional Environment Temperature And Humidity Sensor Low Power Consumption wholesale

Professional Environment Temperature And Humidity Sensor Low Power Consumption

China High precision Environment Monitoring System Smoke Sensor Energy Saving wholesale

High precision Environment Monitoring System Smoke Sensor Energy Saving

China Environment Monitoring System Door Sensor For Door Open Alarm / Controlling LED Lamp On Off​ wholesale

Environment Monitoring System Door Sensor For Door Open Alarm / Controlling LED Lamp On Off​

Inquiry Cart 0