Blue Parking Payment Machine Automatic Car Park Barriers Motor
1. Manual release
2. Machine core with compression spring, effectively avoids the accidents caused by spring
breaking
3. Die-casting aluminum alloy motor, precision and good at thermal radiating
4. Motor cooling fan, solving the problem of heat-protection
5. Double safety limit switches (photoelectricity limit switch/motor memory sensor)
6. Reversing on obstacle
7. Auto-closing
8. Support the INFRARER PHTOCELL for anti-bumping function (optional)
9. Support the external and internal VEHICLE LOOP DETECTOR (optional)
10. Traffic light interface
11. Wire control (switch signal)/ Remote control (418MHZ)
12. RS485 communication module (optional)
Model Selection and Differences
Specifications
Model | WST1211 |
Working Temperature | -40℃~+75℃ |
Voltage | 220V±10%, 110V±10%, 50/60HZ |
Rated power | 80W |
Relative humidity | ≤90% |
Remote control distance | ≥30m |
Net weight | 48kgs |
Speed | 1S,1.8S,3S, 6S |
Max boom length | 6 meters |
Motor Rotational speed | 1400rmp |
Protection Degree | IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic
barrier gate no action?
A | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier
gate will move but even when it is at right position, the motor
still running and not stop?
A | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach
right position (90° vertical & 180° horizontal)?
A. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90° vertical and 180° horizontal |
Why choose us?
1. OEM Brand, Logo, Label available
2. 1 Year Standard Warranty, excellent after-sales service
3. 24h*7d at your service to give you best support
4. Detailed installation manual and wiring diagram to make
everything be easy
5. Fast finishing time for you to become more competitive at your
local market :3-5 days for small order.
Contact us for pricelist and catalog:
Sue Zhang
Email:sue@wonsunbarrier.com
Skype:SueZhang729
Whatsapp:+86 158 7925 9831
Shenzhen Wonsun Machinery & Electrical Technology Co. Ltd
![]() |